Full Autodiagnosis Systems 



ANALY-0010

Omnibus 800 is a multifunction station on PERSONAL COMPUTER for integrating several operations a single instrument.
Thanks to the "iconised" graphics, the operator can immediately determine the desired function which makes the whole system easy to use.


The Tests Currently Integrated Are:
Exhaust gas analysis
(with connection to gas module AGS 200)
Opacity analysis
(with connection to opacimeter module OPA 100)
Oscilloscope
(with use of Oscilloscope cables)
Autodiagnosis
(with connection to OMNI/RIC)
Other functions
(brake tester, etc.)


ANALY-0020

Power Supply
From 10 to 16 Vdc (Battery)

Communications

 
ECP Parallel Port (PC Printer Port)
  Serial data Transmission

General Features
Size 200x180x55 mm
Weight 0.5 Kg

Oscilloscope Features

2 channels.
Input laboratory single:
Range form - 500V to +500V peak
Sensitivity form 0,2/div to 150V/div
Time base from 0,2ms/div to 1s/div
Input primary single:
Range form - 500V to +500V peak
Sensitivity form 40/div to 160V/div
Time base from 2ms/div to 20ms/div
Input secondary single:
Range form 0V a  +50V peak
Sensitivity form 2KV/div to 1KV0V/div
Time base from 2ms/div to 20ms/div



 

RPM input
Trigger position adjustment
Freeze view
sample waves comparing
Check lambda probe
Check alternator diodes
Conventional injection function
Dis injection function (polarity self-detection)

Multimeter Features
● Ohm meter autoranging from 0 ohm to 2 Mohm
Volt meter autoranging from 100Vdc to 100Vdc

ANALY-0030

Technical Features:
Measuring chamber pressure check
Measuring chamber temperature control at 90C
Dirty slide self check
Internal enclosure temperature control
Automatic Span calibration setting
Automatic Zero setting
Five minutes heating time [@ 20C]
Internal rpm counter by pick-up reception of radio signal
Internal thermometer by PT100 probe or
reception of radio signal
Communication Ports RS232 and RS485

Power Supply
From 10 a 16 Vdc (Battery)
Current  1 Adc (Heating off)
                  
8 Adc (Heating off)

General Features
Temperature range from 5 to 40C
Size 200x140x430 mm
Weight 5 Kg

 

 

Measurement Range

Opacity: 099.9 % res. 0.1
09.99 m-1 res. 0.01
RPM:

3009990 rpm

res. 10
Oil Temp.: 20150 C res. 1
Smoke Temp.: 20400 C

res. 1



ANALY-0040


Technical Features:
Measuring gas flow 4L/min
Automatic continuous moisture outlet
Semiautomatic sealing self test
Flow control test
O2 sensor exhausted self checking
Ambient pressure self compensating
(range from 850mB to 1050mB)
Automatic Span calibration (with sample gas bottle)
Automatic Zero setting
Less than ten minutes heating time [@ 20C]
Response time <10 s
Internal rpm counter by pick-up or reception
of  radio signal
Internal thermometer by PT100 probe or
reception of radio signal
Communication Ports RS232 and RS485

Power Supply
From 10 a 16 Vdc (Battery)
Current  1,5 Adc

General Features
Temperature range from 5 to 40C
Size 200x140x430 mm
Weight 5 Kg    


 

Measurement Range

CO 09.99 % res. 0,01
CO2

019,9 %

res. 0,1
HC 09999 ppm res. 1
019990 ppm res.10
O2 03,99 %

res. 0.01

4,025,0 % res. 0.1
LAMBDA 0,5001,999

res. 0,001

DERHZ 30019990 rpm

res. 10

Motertemp 20150 C

res. 1